English      Deutsch                          Sitemap      Search      Contact     
 
Indoor Cables

Tight buffer or semi tight buffer

Cables intended mainly for indoor use, however all cables have a weather proof and UV stabilised outer sheet, and can as such be used outdoor as well.

Cables with 900 micron tight buffer:

D02     2 - 24 fibres: Aramid yarns and FireRes® sheath. IEC 60332-3C fire rating.  DQ

D06     24 - 96 fibres: 6 fibre units w. aramid yarns, stranded around a central core, w. FireRes® sheath.  IEC 60332-3C fire rating. DQ

D12     2 - 24 fibres: Glass yarns and FireBur® sheath. IEC 60332-1 fire rating. DQ

D03     2 - 24 fibres: B reak-out cable w ø2.0 mm units, stranded around a central core, w. FireRes® sheath. IEC 60332-3C fire rating. DQ

Cables with 900 micron semi tight fibre (gel filled type).

Cables D06 and D03 are available with semi tight buffer as an option, together with the following special designs.

DQ denotes standard cable


Central tube

Cables intended mainly for indoor use, however all cables have a weather proof and UV stabilised outer sheet, and can as such be used outdoor as well.

E05    2 - 24 fibre UNI tube cable, aramid yarns, FireRes ® sheath. IEC 60332-3C fire rating (up to 12 fibres). DQ

E17    2 - 24 fibres GARPE 5 FR plus,  glass elements, FireRes® sheath, IEC 60332-3C fire rating. 

E15    2 - 24 fibre GARPE ® 4 FR plus, glass elements, FireRes ® sheath, IEC 60332-3C and UL 1666 fire rating.

The cables in a glance:

Cable Rated installation tensile strength Diameter Rodent protection Water blocked
E05 DQ 1000 N 6,0/6,5 mm None No
E17 1500 N 7,5/8,0 mm Class 1 Yes
E15 3000 N 9,5/10,0 mm Class 2 Yes

DQ
denotes standard cable


Stranded loose tube

Cables intended mainly for indoor use, however all cables have a weather proof and UV stabilised outer sheet, and can as such be used outdoors as well. The cables are semi dry longitudinal water blocked using swell able materials. The cables features a FireRes ®   sheath and fulfill IEC 60332-3C.

N06    6 - 264 fibre stranded loose tube cable, FireRes ®   sheath, IEC 60332-3C fire rating DQ

N03    6 - 96 fibre stranded loose tube cable, heavy layer of glass yarns, FireRes ®   sheath, IEC 60332-3C fire rating DQ

I09      6 - 96 fibre stranded loose tube cable, inner FireBur ®   sheath, steel tape armouring,  outer FireRes ®   sheath, IEC 60332-3C fire rating.

The cables in a glance:

Cable Rated installation tensile strength Diameter Rodent protection Water blocked
N06 DQ 1800 N Fibre count dependent None Yes
N03 DQ 6000 N Fibre count dependent Class 2 Yes
I09 1800 N Fibre count dependent Class 1 Yes 

DQ
denotes standard cable


UC 2000 types, tight buffer or semi tight buffer

J-V(ZN)H simplex tight buffered Universal Cable UC2000 S 1G .. FLEX / FO Simplex Cable J-V(ZN)H 1G ..

J-V(ZN)H duplex semi tight buffered Universal Cable UC2000 T 2G .. / FO Duplex Cable (Twin) J-V(ZN)H 2G ..

J-V(ZN)H duplex tight Universal Cable UC2000 T 2G .. FLEX / FO Duplex Cable (Twin) J-V(ZN)H 2G ..

J-V(ZN)HH duplex semi tight buffered Universal Cable UC2000 F 2G .. / FO Duplex Cable (Flat) J-V(ZN)HH 2G ..

J-V(ZN)HH duplex tight buffered Universal Cable UC2000 F 2G ..FLEX / FO Duplex Cable (Flat) J-V(ZN)HH 2G ..

J-V(ZN)H Mini Breakout Universal Cable UC2000 D nG .. / FO Mini-Breakout Cable J-V(ZN)H nG ..

J-V(ZN)HH Breakout Universal Cable UC2000 B nG .. / FO Break-out Cable J-V(ZN)HH nG ..

I-VH11Y2K200/230 LWL-Breakout-Kabel J-V(ZN)H11Y2K200/230