Universal Cables

Tight buffer or semi tight buffer

Cables which is longitudinally water blocked *) for outdoor use, but has a flame retardant sheathing for fire rating as mentioned under the specific cable.

*) Note: some exceptions exist, see  the individual descriptions.

D15    2 - 24 fibres: Glass elements, FireRes® sheath. IEC 60332-3C fire rating, WB according to IEC 60794 DQ

D16    2 - 24 fibres: Heavy duty cable; two longitudinal FRP elements, LSZH sheath. IEC 60332-3C fire rating, WB according to IEC 60794.

D11    2 - 24 fibres: "Wet duct cable"; aramid yarns, inner FireRes® sheath, glass elements reinforcement, outer FireBur® sheath. IEC 60332-1 fire rating, core non water blocked.

D09    2 - 16 fibres: Aramid yarns, Inner FireRes® sheath, steel tape armouring, outer FireBur sheath. IEC 60332-1 fire rating, non water blocked.

DQ denotes standard cable


Central tube

Cables which are longitudinally water blocked *) for outdoor use, but has a flame retardant sheathing for fire rating as mentioned under the specific cable.

*) Note: some exceptions exist, see  the individual descriptions.

E14    2- 24 fibre GARPE® 6 FR, glass elements, FireBur® sheath, IEC 60332-1 fire rating. DQ

E10    2 - 24 fibr e GARPE® 5 F R, glass elements, FireBur® sheath, IEC 60332-1 fire rating . DQ

E11    2 - 24 fibre GARPE ® 4 F R, glass elements , FireBur ® sheath, IEC 60332-1 fire rating.

E07    2 - 24 fibre, glass yarns, corrugated steel tape armouring, FireBur ® sheath, IEC 60332-1 fire rating ; not longitudial water blocked. DQ

The cables in a glance:

Cable Rated installation tensile strength Diameter Rodent protection Water blocked
E14 DQ 1000 N 6,0/6,5 mm class 1 Yes
E10 DQ 1500 N 7,5/8,0 mm class 1 Yes
E11 3000 N 9,0/9,5 mm class 2 Yes
E07 DQ 1000 N 8,5/9,5 mm class 3 No

DQ
denotes standard cable


Stranded loose tube

Cables intended mainly for combined indoor and outdoor use = universal use. The cables are semi dry longitudinal water blocked using swell able materials. The cables features a FireBur ®   sheath and fulfil IEC 60332-1C.

N01    6 - 264 fibre stranded loose tube cable, FireBur ®   sheath, IEC 60332-1 fire rating DQ

N05    6 - 216 fibre stranded loose tube cable, medium layer of glass yarns, FireBur ®   sheath, IEC 60332-1 fire rating DQ

N02    6 - 264 fibre stranded loose tube cable, heavy layer of glass yarns, FireBur ®   sheath, IEC 60332-1 fire rating

I08    6 - 96 fibre stranded loose tube cable, inner MDPE sheath, steel tape armouring,  outer FireBur ®   sheath, IEC 60332-1 fire rating.

The cables in a glance:

Cable Rated installation tensile strength Diameter Rodent protection Water blocked
N01 DQ 1800 N Fibre count dependent None Yes
N05 DQ 4800 N Fibre count dependent Class 2/3 Yes
N02 6000 N Fibre count dependent Class 2 Yes
I08 1800 N Fibre count dependent Class 1 Yes

DQ
denotes standard cable


UC2000 types, tight buffer or semi tight buffer

U-V(ZN)HQBH 3000N
Universal Cable UC2000 B-A nG .. FRNC / FO Break-out Cable U-V(ZN)HQBH 3000N nG ..


UC2000 types, central tube

U-DQ(ZN)BH 1000N
Universal Cable UC2000 CT-AL nG .. / FO Cables with loose tube U-DQ(ZN)H 1000N

U-DQ(ZN)BH 1500N Universal Cable UC2000 CT-A nG .. / FO Cables with loose tube U-DQZN)BH 1500N

U-DQ(ZN)BH 3000N UC2000 CT-A+ nG… FRNC / FO Universal Cable with central loose tube U-DQ(ZN)BH 3000N


UC2000 types, stranded loose tube

U-DQ(ZN)BH 6000N
Universal Cable UC2000 ST-A nG .. / FO Cables with loose tube U-DQZN)B 6000N