Cables which is longitudinally water blocked *) for outdoor use, but has a flame retardant sheathing for fire rating as mentioned under the specific cable. *) Note: some exceptions exist, see the individual descriptions. D15 2 - 24 fibres: Glass elements, FireRes® sheath. IEC 60332-3C fire rating, WB according to IEC 60794 DQ D16 2 - 24 fibres: Heavy duty cable; two longitudinal FRP elements, LSZH sheath. IEC 60332-3C fire rating, WB according to IEC 60794. D11 2 - 24 fibres: "Wet duct cable"; aramid yarns, inner FireRes® sheath, glass elements reinforcement, outer FireBur® sheath. IEC 60332-1 fire rating, core non water blocked. D09 2 - 16 fibres: Aramid yarns, Inner FireRes® sheath, steel tape armouring, outer FireBur sheath. IEC 60332-1 fire rating, non water blocked. DQ denotes standard cable
Cables which are longitudinally water blocked *) for outdoor use, but has a flame retardant sheathing for fire rating as mentioned under the specific cable. *) Note: some exceptions exist, see the individual descriptions. E14 2- 24 fibre GARPE® 6 FR, glass elements, FireBur® sheath, IEC 60332-1 fire rating. DQ E10 2 - 24 fibr e GARPE® 5 F R, glass elements, FireBur® sheath, IEC 60332-1 fire rating . DQ E11 2 - 24 fibre GARPE ® 4 F R, glass elements , FireBur ® sheath, IEC 60332-1 fire rating. E07 2 - 24 fibre, glass yarns, corrugated steel tape armouring, FireBur ® sheath, IEC 60332-1 fire rating ; not longitudial water blocked. DQ The cables in a glance:
DQ denotes standard cable
Cables intended mainly for combined indoor and outdoor use = universal use. The cables are semi dry longitudinal water blocked using swell able materials. The cables features a FireBur ® sheath and fulfil IEC 60332-1C. N01 6 - 264 fibre stranded loose tube cable, FireBur ® sheath, IEC 60332-1 fire rating DQ N05 6 - 216 fibre stranded loose tube cable, medium layer of glass yarns, FireBur ® sheath, IEC 60332-1 fire rating DQ N02 6 - 264 fibre stranded loose tube cable, heavy layer of glass yarns, FireBur ® sheath, IEC 60332-1 fire rating I08 6 - 96 fibre stranded loose tube cable, inner MDPE sheath, steel tape armouring, outer FireBur ® sheath, IEC 60332-1 fire rating. The cables in a glance:
DQ denotes standard cable
U-V(ZN)HQBH 3000N Universal Cable UC2000 B-A nG .. FRNC / FO Break-out Cable U-V(ZN)HQBH 3000N nG ..
U-DQ(ZN)BH 1000N Universal Cable UC2000 CT-AL nG .. / FO Cables with loose tube U-DQ(ZN)H 1000N U-DQ(ZN)BH 1500N Universal Cable UC2000 CT-A nG .. / FO Cables with loose tube U-DQZN)BH 1500N U-DQ(ZN)BH 3000N UC2000 CT-A+ nG… FRNC / FO Universal Cable with central loose tube U-DQ(ZN)BH 3000N
U-DQ(ZN)BH 6000N Universal Cable UC2000 ST-A nG .. / FO Cables with loose tube U-DQZN)B 6000N |